Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
Radiol. bras ; 41(5): 283-288, set.-out. 2008. ilus, tab
Article in English, Portuguese | LILACS | ID: lil-496930

ABSTRACT

OBJETIVO: Verificar se a mamoplastia de aumento pela via transaxilar apresenta potencial de prejudicar a identificação futura do linfonodo sentinela. MATERIAIS E MÉTODOS: Estudo prospectivo controlado em que foram selecionadas 22 pacientes divididas em grupo pós-mamoplastia e grupo controle, totalizando 43 mamas (22 no grupo pós-mamoplastia e 21 no grupo controle) avaliadas por meio de linfocintilografia imediatamente após injeções periareolares de fitato-99mTc. Os testes estatísticos consideraram como diferenças significativas valores de p < 0,05. RESULTADOS: Todas as mamas do grupo pós-mamoplastia apresentaram drenagem linfática para a cadeia axilar, sem diferença com o grupo controle (p = 0,488). A média de linfonodos captantes foi de 1,27 ± 0,46 no grupo pós-mamoplastia e 1,33 ± 0,58 no grupo controle (p = 0,895). A média de tempo para visualização do primeiro linfonodo foi de 3,14 ± 4,42 minutos no grupo pós-mamoplastia e 5,48 ± 5,06 minutos no grupo controle, novamente sem diferença significativa (p = 0,136). CONCLUSÃO: A mamoplastia de aumento pela via transaxilar não acarretou prejuízo na identificação futura do linfonodo sentinela.


OBJECTIVE: To evaluate the potential influence of transaxillary augmentation mammoplasty on future detection of sentinel lymph node. MATERIALS AND METHODS: Prospective controlled study where 22 patients were selected and divided into two groups (post-mammoplasty and control) corresponding to 43 breasts (22 in the post-mammoplasty group and 21 in the control group) evaluated by lymphoscintigraphy immediately after periareolar 99mTc-phytate injections. In the statistical analysis, p values < 0.05 were considered as significant. RESULTS: All the breasts in the post-mammoplasty group presented lymphatic drainage to the axillary chain, with no difference as compared with the control group (p = 0.488). The average number of hot lymph nodes was 1.27 ± 0.46 in the post-mammoplasty group, and 1.33 ± 0.58 in the control group (p = 0.895). The mean time required to visualize the first lymph node was 3.14 ± 4.42 minutes in the post-mammoplasty group, and 5.48 ± 5.06 minutes in the control group (p = 0.136). CONCLUSION: Transaxillary augmentation mammoplasty did not affect the future detection of sentinel lymph node.


Subject(s)
Humans , Female , Adult , Breast Implants , Breast Neoplasms , Drainage , Lymph Nodes , Mammaplasty , Brazil , Diagnostic Techniques and Procedures , Prospective Studies , Sentinel Lymph Node Biopsy
SELECTION OF CITATIONS
SEARCH DETAIL